How to Find the Right Dell EMC SSD Part Number: DP/N, EMC 005 and Manufacturer Models

2026-11-01

Short answer: a Dell EMC drive can carry three different part numbers: the Dell part number (DP/N, e.g. 0TDNP7), the EMC part number (005xxxxxx, used on Unity, VNX and PowerMax arrays) and the manufacturer part number printed by Samsung, Kioxia or Seagate (e.g. KPM5XRUG1T92). Quote the number your server or array actually reports, and you will get a drive with the right firmware and carrier the first time.

Why one drive has several part numbers

Dell and Dell EMC do not build SSDs. They buy drives from Samsung, Kioxia (formerly Toshiba Memory), Micron, Seagate and others, load Dell-qualified firmware, and assign their own part numbers. The same physical drive can therefore appear under:

  • Dell DP/N – a 5- or 6-character code such as 0TDNP7, 0HWRH4 or 02XVX2. The leading zero is often dropped in listings (TDNP7 = 0TDNP7).
  • EMC part number – a 9-digit number starting with 005 (for example 005053702). These belong to the legacy EMC storage line: Unity, VNX, XtremIO and PowerMax.
  • Manufacturer model – the OEM's own model string, such as KPM5XRUG1T92 (Kioxia PM5) or MZILT7T6HALA (Samsung PM1643).

Where to find the part number

  1. The drive label. Dell labels show "DP/N" followed by the part number, plus the manufacturer model and firmware revision.
  2. iDRAC or OpenManage. On PowerEdge servers, Storage → Physical Disks lists the model, Dell part number and firmware.
  3. Unisphere or array logs. On Unity and VNX systems, the disk view shows the EMC 005 part number and TLA.
  4. The original invoice or service tag. Dell support can list the parts shipped with a service tag.

Which number should you quote?

Use the number your platform recognises:

  • PowerEdge servers: quote the Dell DP/N. Dell firmware avoids "non-Dell drive" warnings in iDRAC and keeps fan and health reporting normal.
  • Unity, VNX, PowerMax arrays: quote the EMC 005 number. Arrays check firmware and may reject a drive with generic or server firmware.
  • White-box or generic servers: the manufacturer model is enough, and generic firmware is often cheaper.

Check these four things before you order

  • Interface: SAS 12Gb, SAS 24Gb, SATA or NVMe U.2. A SAS drive will not work on a SATA-only backplane.
  • Endurance class: read-intensive (about 1 DWPD) or mixed-use (about 3 DWPD). Match what you are replacing in write-heavy arrays.
  • Carrier or tray: PowerEdge 14G/15G/16G and Unity use different trays. Ask whether the tray is included.
  • Condition: new, open box, refurbished or used. Ask for a SMART report on pulled drives.

Common Dell EMC part numbers we quote

Popular requests include 0TDNP7 (1.92TB SAS 12Gb), 0HWRH4 (1.92TB NVMe Gen5), 0J91CR (15.36TB NVMe U.2) and EMC numbers such as 005053702. Browse the full Dell EMC drive collection.

Need a quote?

Send the part number from the label or iDRAC, the quantity and your destination. We confirm the matching firmware, condition and lead time within 24 hours. Request a quote →

Not sure which drive fits your server? Use our server drive compatibility finder or request a bulk / project quote.