Server Drive Compatibility Finder — Dell, HPE and Lenovo

Pick your server, see which drive types its bays and controllers take, and send us the model or service tag. We return a matched list — data drives, boot drives and carriers — in one quote.

Fastest route: send your server model, bay configuration (or Dell service tag / HPE serial), how many drives and what capacity. We reply within 4 working hours.

Send your server model for a matched drive list

Dell PowerEdge

ServerFront bays (per Dell)ControllersBootGuide
R740 (14G)Up to 16 × 2.5" or 8 × 3.5" SAS/SATAPERC H330, H730P, H740P, HBA330BOSS-S1 (SATA M.2)R740 guide
R740xd (14G)Up to 24 × 2.5" (up to 24 NVMe with all-NVMe backplane) or 12 × 3.5"; mid and rear baysPERC H330, H730P, H740P, HBA330BOSS-S1 (SATA M.2)R740xd guide
R750 (15G)2.5" SAS/SATA/NVMe Gen4 and 3.5" optionsPERC 11 (H755, H755N), HBA355iBOSS-S2 (SATA M.2)R750 guide
R660 (16G, 1U)Up to 10 × 2.5" plus 2 rear; E3.S optionsPERC 12 H965i, PERC 11, HBA355iBOSS-N1 (NVMe M.2)16G guide
R760 (16G)12 × 3.5", or 8/16/24 × 2.5" SAS/SATA/NVMe (Gen4 U.2), or 16 × E3.S Gen5PERC 12 H965i, PERC 11 H755/H755N, H355, HBA355iBOSS-N1 (NVMe M.2)R760 guide

Shop Dell PowerEdge server drives. For Dell labels and DP/N numbers, see how to read Dell part numbers; for boot cards, see BOSS-S1 vs S2 vs N1.

HPE ProLiant

GenerationDrive carrierWhat to matchGuide
Gen8 – Gen10 Plus (e.g. DL360, DL380)Smart Carrier (SC); SCN for NVMe; SCC for 2.5" in 3.5" baysOption (-B21) or spare (-001) number, interface, RI/MU classHPE part numbers
Gen11 – Gen12 (e.g. DL360 Gen11, DL380 Gen11)Basic Carrier (BC); EC1 for E3.SBC option numbers; SC drives do not fit BC baysHPE part numbers

HPE servers may raise fan speed with non-HPE drives, so we recommend HPE-branded drives for ProLiant. Shop HPE ProLiant server drives.

Lenovo ThinkSystem

FamilyWhat to matchGuide
SR630 / SR650 and V2 / V3 rack servers4XB7A option or FRU number, HS (hot-swap) tray, interface and endurance classLenovo part numbers
ST50 / ST250 towers and entry systemsHS vs NHS (non-hot-swap) variant for the chassisLenovo part numbers

Shop Lenovo ThinkSystem server drives.

Storage arrays

Arrays usually accept only their own qualified part numbers, often dual-port drives with array firmware. Send the array model and the drive label. See NetApp AFF/FAS drives, Dell EMC PowerStore and dual-port NVMe explained.

Five checks before you order drives for a server

  1. Backplane type: SAS/SATA only, universal (SAS/SATA/NVMe), NVMe-only or EDSFF (E1.S/E3.S). See form factors explained.
  2. Controller: RAID card, HBA or direct NVMe. See RAID for SSDs and NVMe.
  3. Carrier: generation-specific trays (Dell 14G–16G, HPE SC vs BC, Lenovo HS vs NHS).
  4. OEM vs generic: vendor-branded drives give full iDRAC/iLO/XClarity reporting. See OEM vs generic SSDs.
  5. Sector format and firmware: 512e for VMware SSDs before ESX 9.0. See 512e vs 4Kn.

Get a matched drive list for my server

Questions buyers ask

Can you tell which drives fit from a Dell service tag?

Yes. Send the service tag and we check the original bay, backplane and controller configuration before quoting.

Do you include drive trays or carriers?

On request. Many replacement drives are sold bare; tell us whether you need carriers and for which server generation.

Will generic (non-OEM) drives work in my server?

Usually yes for data in Dell and Lenovo servers, with a non-certified notice. HPE servers may raise fan speed. Arrays usually reject them.

Can I mix drive models in one server?

Yes across different volumes. Within one RAID set, use one model and firmware.

Do you supply boot drives for BOSS cards?

Yes: SATA M.2 for BOSS-S1/S2 and NVMe M.2 for BOSS-N1.

Buying for many servers at once? See bulk and project quotes.