Dell BOSS-S1 vs BOSS-S2 vs BOSS-N1: M.2 Boot SSD Guide for PowerEdge
By the SSDtrader Team · Updated 10 November 2026 · Server compatibility guides
The short answer: Dell BOSS (Boot Optimized Storage Solution) cards hold two 80mm M.2 SSDs as a mirrored boot volume, so the operating system does not use a front drive bay. BOSS-S1 (14th-generation PowerEdge, e.g. R640/R740) takes two M.2 SATA SSDs on a PCIe card with no hot-plug. BOSS-S2 (15th generation, e.g. R650/R750) also uses M.2 SATA but adds hot-plug carriers and status LEDs. BOSS-N1 (16th generation, e.g. R660/R760) switches to M.2 NVMe, supports 480GB or 960GB read-intensive drives, and offers hardware RAID 1 or single-drive RAID 0 with hot-plug on rear-facing versions.
Disclosure: SSDtrader sells M.2 enterprise SSDs and Dell server drives. Specifications below come from Dell's BOSS-N1 data sheet, Dell InfoHub articles and the BOSS user guides linked in the sources. We are not a Dell partner, and compatibility of non-Dell-branded drives is not guaranteed by Dell.
Almost every Dell PowerEdge server sold since 2017 can boot from a BOSS card. It is a small, dedicated RAID controller for two M.2 SSDs. It keeps the hypervisor or operating system on a mirrored pair that never competes with data drives for front bays or for the main PERC RAID controller.
The three generations look similar on a parts list, but they are not interchangeable. They use different drive interfaces, different mounting and different firmware. A BOSS-S2 drive will not work in a BOSS-N1 slot, and a BOSS-N1 module does not fit a 14th-generation server. This guide explains the differences, which servers use which card, what drives each one accepts and how to replace a failed boot SSD without reinstalling.
What is a Dell BOSS card?
BOSS stands for Boot Optimized Storage Solution. It is a simple hardware RAID controller with exactly two M.2 slots and one job: present a single bootable virtual disk to the server. It does not support RAID 5, does not have cache memory and is not meant for application data. Dell positions it for operating systems and hypervisors such as VMware ESXi, Windows Server and Linux.
The main benefits are:
- All front bays stay free for data drives.
- Boot is independent of the data RAID controller, so a PERC firmware problem or a data-array rebuild does not affect the OS volume.
- Mirroring protects the OS from a single SSD failure.
BOSS-S1 vs BOSS-S2 vs BOSS-N1 compared
| Feature | BOSS-S1 | BOSS-S2 | BOSS-N1 |
|---|---|---|---|
| PowerEdge generation | 14th (e.g. R640, R740, R740xd) | 15th (e.g. R650, R750, R6525, R7525) | 16th (e.g. R660, R760, R7625) |
| M.2 interface | SATA 6Gb/s | SATA 6Gb/s | NVMe (PCIe Gen3 x2 per drive) |
| M.2 length | 80mm (2280) | 80mm (2280) | 80mm (2280) |
| Dell-supported drive sizes | 240GB, 480GB | 240GB, 480GB | 480GB, 960GB (1 DWPD) |
| RAID modes | RAID 1 or non-RAID | RAID 1 or non-RAID | RAID 1 or single-drive RAID 0 (no pass-through) |
| Form | PCIe adapter (low-profile or full-height) or modular | Rear-facing module with two hot-plug carriers | Rear- or front-facing module (monolithic) or internal modular |
| Hot-plug M.2 | No | Yes | Yes on monolithic/rear-facing; no on modular |
| Status LEDs | No | Yes | Yes on monolithic; no on modular |
| Host interface | PCIe Gen2 | PCIe Gen2 | PCIe Gen3 x4 |
The jump from S2 to N1 is mostly about speed and serviceability. NVMe boot drives make little difference to day-to-day running, but they shorten OS installs, patch cycles and the time a hypervisor takes to load modules. Dell's data sheet notes one design change that catches people out: BOSS-N1 drops non-RAID pass-through. A single drive must be configured as a one-drive RAID 0 virtual disk.
Which PowerEdge servers use which BOSS card?
As a rule, the card follows the server generation, which you can read from the model number. In current Dell naming, the second digit is the generation (R640 = 14G, R650 = 15G, R660 = 16G), and the AMD models use a "5" in the last position (R6525, R7625).
- 14G: R440, R540, R640, R740, R740xd, R940 and similar → BOSS-S1.
- 15G: R450, R550, R650, R750, R750xs, R6525, R7525 and similar → BOSS-S2 (some 15G systems also support the S1 adapter).
- 16G: R660, R760, R660xs, R760xs, R6615, R7615, R6625, R7625 and similar → BOSS-N1.
Always confirm against the installation and service manual for your exact server. Some 16G variants are only offered with the internal modular N1, which has no hot-plug. For storage planning on 15G servers, see our PowerEdge R750 SSD compatibility guide.
What M.2 drive does each BOSS card accept?
BOSS-S1 and BOSS-S2 need 80mm M.2 SATA SSDs (B+M key). Dell shipped them with 240GB and 480GB read-intensive drives, commonly Micron 5100/5300 M.2, Intel S4510 M.2 or SK hynix models under Dell part numbers. An NVMe M.2 drive will not be detected.
BOSS-N1 needs 80mm M.2 NVMe SSDs (M key). Dell's data sheet specifies enterprise-class, read-intensive drives at 480GB or 960GB. Common drives inside Dell-branded N1 modules include the Micron 7450 PRO M.2 and Samsung PM9A3 M.2 families. A 22110 drive is too long for the carrier.
A practical note on third-party drives: BOSS controllers often recognise a generic M.2 drive of the right type, but Dell only supports drives on its qualified list, and iDRAC may report a non-Dell drive differently. If you need Dell support coverage, buy the Dell-part-numbered drive. If you are maintaining an out-of-warranty server yourself, a matching generic enterprise drive (for example a Micron 7450 PRO 960GB M.2 2280) is the common route. Test it before you rely on it.
Why are BOSS drives read-intensive?
A boot drive writes very little: logs, patches and occasional crash dumps. Dell specifies 1 DWPD drives for the N1. On a 480GB drive that is about 876 TB of writes over five years, far more than an OS volume will see. There is no reason to pay for a mixed-use drive here. Our read-intensive SSD explainer covers how DWPD ratings are set.
How do you replace a failed SSD on a BOSS card?
The process is similar on S2 and N1 (hot-plug versions):
- In iDRAC (Storage → Physical Disks), identify the failed M.2 drive and its slot (0 or 1).
- On hot-plug models, pull the carrier for the failed slot from the rear module. On S1 or modular N1, power the server down first.
- Move the replacement SSD into the carrier. Use the same capacity or larger; the mirror will only use the original size.
- Re-insert the carrier. BOSS-S2 and BOSS-N1 support automatic rebuild of a degraded mirror when a suitable drive is inserted.
- Watch rebuild progress in iDRAC or with the BOSS CLI (
mvclion S1/S2). Do not reboot during the rebuild if you can avoid it.
Update the controller and drive firmware to Dell's current releases afterwards. Dell's user guides note that BOSS-N1 drives should run the latest firmware.
Can you use a BOSS card for data or caching?
Technically, a RAID 0 or RAID 1 BOSS volume is just a disk, so you can put anything on it. In practice it is a poor choice for data. Capacities are small, the controller has no cache, and per-drive bandwidth on the N1 is PCIe Gen3 x2. For a vSAN cache tier, a database or a scratch volume, use a proper NVMe drive in a front bay instead. See U.2/U.3 NVMe SSDs or SATA SSDs for data drives.
Buying checklist for BOSS boot drives
- Interface: SATA M.2 for S1/S2; NVMe M.2 for N1. This is the most common mistake.
- Length: 80mm (2280) only.
- Capacity: 240GB/480GB on S1/S2; 480GB/960GB on N1. Larger drives may work but are not in Dell's list.
- Carrier: hot-plug carriers are separate parts on S2 and N1. Replacement drives usually do not include one.
- Two matching drives for a new mirror. Same model and firmware keeps rebuild behaviour predictable.
- Condition and health: for used drives, check percentage used and media errors in SMART before installing.
Send your server model and BOSS version through the quote form and we will match drives to it. We reply within four working hours; there is no minimum order. Dell server drives we list are grouped in Dell PowerEdge server drives.
Not sure which drive fits your server? Use our server drive compatibility finder or request a bulk / project quote.
Questions buyers ask
Can I put an NVMe M.2 SSD in a BOSS-S2?
No. BOSS-S1 and BOSS-S2 only support M.2 SATA SSDs. NVMe boot needs a BOSS-N1 in a 16th-generation server.
Does BOSS-N1 support pass-through (non-RAID)?
No. According to Dell, BOSS-N1 supports hardware RAID 1 or a single-drive RAID 0 virtual disk, with no pass-through mode.
Can I install a BOSS-N1 in a PowerEdge R750?
Not as a supported configuration. BOSS-N1 is designed for 16th-generation servers. 15th-generation servers such as the R750 use BOSS-S2.
What size M.2 drive should I use for VMware ESXi on BOSS?
Dell ships 480GB for most configurations. ESXi 8 recommends a boot device of at least 128GB for its OSDATA partition, so 240GB is the practical minimum and 480GB leaves room.
Are BOSS drives hot-swappable?
On BOSS-S2 and on rear- or front-facing BOSS-N1 modules, yes. BOSS-S1 and the internal modular BOSS-N1 require the server to be powered off.
Do I need two drives?
No, but one drive gives no redundancy. With a single drive, BOSS-S1/S2 can run non-RAID and BOSS-N1 runs a one-drive RAID 0.
Related guides
- Dell PowerEdge R750 SSD compatibility guide
- Micron 7450 PRO vs MAX explained
- How to read Dell EMC SSD part numbers