How to Check Enterprise SSD Health: SMART, NVMe Percentage Used and Wear
By the SSDtrader Team · Updated 10 November 2026 · How-to guides
The short answer: To check an enterprise SSD's health, read its SMART or NVMe health log. On Linux, run sudo nvme smart-log /dev/nvme0 for NVMe drives or sudo smartctl -a /dev/sdX for SAS and SATA drives. Focus on four numbers: percentage used (endurance consumed, 0–100%+), available spare (should stay well above its threshold), media errors (should be 0), and data units / total bytes written. Also check that the critical warning field is 0. On Dell and HPE servers, iDRAC and iLO show the same data as remaining rated write endurance.
Disclosure: SSDtrader grades every used and refurbished drive using these SMART fields. This guide describes standard tools (smartmontools, nvme-cli) and fields defined in the NVMe specification. Command output examples are illustrative and use made-up values.
Whether you are buying a used enterprise SSD, auditing a fleet before a refresh or deciding which drives to retire, the drive itself is the best witness. Every NVMe SSD keeps a standard health log, and SAS and SATA SSDs keep SMART data. Reading it takes a minute and tells you how much endurance has been used, whether the flash is failing, and whether the drive was mistreated.
This guide shows the exact commands for Linux, Windows and VMware ESXi, explains each field and gives the thresholds we use when grading drives.
Which tools do you need?
- smartmontools (
smartctl) — reads SATA, SAS and NVMe drives on Linux, Windows, macOS and FreeBSD. Version 7.0 or newer has good NVMe support. - nvme-cli (
nvme) — the reference NVMe management tool on Linux. It reads the NVMe health log and vendor-specific logs. - Vendor tools — Samsung Magician DC, Solidigm Storage Tool, Micron Storage Executive, Kioxia/WD/Seagate utilities. Useful for firmware updates and vendor wear logs.
- Server management — Dell iDRAC, HPE iLO, Lenovo XClarity. They show wear without installing anything on the host.
How do you check an NVMe SSD's health on Linux?
List drives, then read the health log:
sudo nvme list
sudo nvme smart-log /dev/nvme0
Typical output (illustrative values):
critical_warning : 0
temperature : 38 C
available_spare : 100%
available_spare_threshold : 10%
percentage_used : 3%
data_units_read : 812,345,678
data_units_written : 401,234,567
host_read_commands : 9,876,543,210
host_write_commands : 4,567,890,123
power_cycles : 42
power_on_hours : 21,904
unsafe_shutdowns : 17
media_errors : 0
num_err_log_entries : 0
smartctl -a /dev/nvme0 shows the same fields in a slightly different layout.
What does each NVMe health field mean?
| Field | Meaning | What to look for |
|---|---|---|
| critical_warning | Bit flags for spare below threshold, over-temperature, reliability degraded, read-only mode, backup capacitor failure | Must be 0. Any non-zero value needs investigation |
| available_spare | Percentage of spare blocks remaining | Near 100% on healthy drives; it falls as blocks are retired |
| available_spare_threshold | Level at which the drive raises a warning | If available_spare approaches this, replace the drive |
| percentage_used | Vendor estimate of rated endurance consumed | 0–100%. Can exceed 100%; the drive may still work but is beyond rating |
| data_units_written | Host writes in units of 1,000 × 512 bytes (512,000 bytes) | Multiply by 512,000 to get bytes. Compare with rated TBW |
| power_on_hours | Total hours powered | Shows age. Data-centre drives often have 20,000–40,000 h |
| unsafe_shutdowns | Power lost without a clean shutdown | High counts are common in labs; check alongside media errors |
| media_errors | Unrecovered data-integrity errors | Should be 0. Any non-zero count is a red flag |
| num_err_log_entries | Entries in the error log | Non-zero is often benign (e.g. unsupported commands); inspect with nvme error-log |
How to convert data units written to terabytes
The NVMe specification defines one data unit as 1,000 units of 512 bytes. So:
TB written = data_units_written × 512,000 ÷ 1012
In the example above, 401,234,567 × 512,000 ≈ 205 TB written. On a 3.84TB drive rated for 1 DWPD (about 7,000 TB over five years), that is roughly 3% of rated endurance, which matches the percentage_used value. When the two disagree a lot, trust percentage_used, because it is based on actual NAND wear, including internal write amplification.
How do you check a SAS SSD's health?
sudo smartctl -a /dev/sdb
SAS drives report SCSI log pages rather than ATA attributes. The fields to read are:
- Percentage used endurance indicator — the SAS equivalent of NVMe percentage used.
- Elements in grown defect list — blocks retired since manufacture. Low single digits are acceptable on a large drive; a rising count is not.
- Error counter log — read/write/verify errors. "Total uncorrected errors" should be 0.
- Accumulated power on time and bytes written (shown as gigabytes processed).
If the drive sits behind a hardware RAID controller, smartctl needs a device-type flag, for example -d megaraid,N for Broadcom/Dell PERC controllers or -d cciss,N for older HPE Smart Array, where N is the physical drive number.
How do you check a SATA SSD's health?
SATA SSDs use ATA SMART attributes, and vendors name their wear attribute differently:
| Vendor | Wear attribute (typical) | Notes |
|---|---|---|
| Samsung | 177 Wear_Leveling_Count | Normalised value counts down from 100 |
| Intel / Solidigm | 233 Media_Wearout_Indicator | Normalised value counts down from 100 |
| Micron / Crucial | 202 Percent_Lifetime_Remain (or 173 average erase count) | Check vendor documentation for the model |
| Kioxia / Toshiba | 173 or 231, depending on model | Model-specific |
| Most vendors | 241 Total_LBAs_Written | Multiply by 512 bytes (or the vendor unit) for bytes written |
Also check attributes 5 (reallocated sectors), 187 (reported uncorrectable errors) and 199 (CRC errors). CRC errors usually point to a bad cable or backplane slot, not the drive.
How do you check SSD health on Windows and VMware ESXi?
Windows: install smartmontools for Windows and run smartctl -a /dev/sda or smartctl -a /dev/nvme0 from an administrator prompt. PowerShell's Get-PhysicalDisk | Get-StorageReliabilityCounter shows wear and temperature for many drives without extra software.
VMware ESXi: run esxcli storage core device smart get -d . For NVMe, esxcli nvme device log smart get -A vmhbaX returns the health log.
How do you check SSD wear in iDRAC or iLO?
On Dell PowerEdge servers, open iDRAC → Storage → Physical Disks. Dell-branded SSDs show Remaining Rated Write Endurance as a percentage, which is 100 minus percentage used. HPE iLO and the Smart Storage Administrator show a similar SSD wear gauge and an estimated life remaining. These numbers come from the same SMART data and are a quick way to audit a whole rack.
What thresholds should you use when buying used drives?
These are the grades SSDtrader applies. Use them as a starting point for your own policy.
| Grade | Percentage used | Media / uncorrected errors | Notes |
|---|---|---|---|
| New | 0% | 0 | Factory sealed or unused |
| Open box | 0–1% | 0 | Unpacked or installed briefly |
| Refurbished | ≤ 10% (health ≥ 90%) | 0 | Tested, wiped, firmware checked |
| Used | > 10%, tested working | 0 | Priced by remaining life |
Two practical rules:
- Media errors above zero or a non-zero critical warning means reject, regardless of wear.
- Percentage used matters more than power-on hours. A drive with 40,000 hours and 2% used has more life left than a drive with 8,000 hours and 60% used.
Ask your supplier for a SMART report with each drive. We include one on request with every quote. For the wider buying checklist, see how to buy refurbished enterprise SSDs.
How long will a drive last based on its SMART data?
Divide the remaining endurance by your daily write rate. Example: a 7.68TB, 1 DWPD drive is rated for about 14,000 TB. At 6% used, about 13,160 TB remains. If your server writes 2 TB per day, the rated endurance covers roughly 18 years, so the drive will retire for capacity or performance reasons long before wear-out. The TBW and DWPD guide walks through more examples.
Need tested drives?
Every refurbished drive we sell has its SMART data checked against the grades above. Browse all enterprise SSDs or send your list to the quote form. We reply within four working hours. Drives that arrive dead or faulty are replaced or refunded if reported within 14 days.
Questions buyers ask
What is a good percentage used value for a used SSD?
Under 10% means most rated endurance remains, and that is our refurbished threshold. Higher values are acceptable for read-heavy workloads if the price reflects remaining life and there are no media errors.
Can percentage used go above 100%?
Yes. The NVMe specification allows values up to 255%. A drive above 100% has exceeded its rated endurance; many keep working, but the manufacturer no longer guarantees data retention.
Is power-on hours a good measure of SSD health?
Not on its own. Flash wears from writes, not time. Use percentage used, available spare and media errors.
Why does smartctl show no data for a drive behind a RAID card?
The RAID controller hides drives from the OS. Use smartctl's device-type option (e.g. -d megaraid,N) or the controller's own tools such as perccli, storcli or ssacli.
What does available spare mean?
It is the share of reserve flash blocks still unused. When blocks wear out, the drive replaces them from this pool. A steady decline signals the drive is ageing faster than normal.
How often should I check SSD health?
Monitoring tools can poll SMART daily. For manual checks, quarterly is common, and always check before redeploying or reselling a drive.
Related guides
- Enterprise SSD lifespan: TBW and DWPD explained
- How to buy refurbished enterprise SSDs safely
- Micron 7450 PRO vs MAX
- Hard drive lifespan, MTBF and AFR