HPE SSD Part Numbers Explained: -B21 vs -001, SC vs BC Carriers, RI/MU/WI
By the SSDtrader Team · Updated 10 November 2026 · Part number guides
The short answer: An HPE server drive can carry three numbers. The option part number ends in -B21 (e.g. P40499-B21) and is the orderable kit with carrier. The spare part number ends in -001 (e.g. P41558-001) and is the service replacement. The HPE model number is printed on the drive (e.g. VK000150GWCNN). The description also tells you the workload class (RI read-intensive, MU mixed-use, WI write-intensive) and the carrier. SC (Smart Carrier) fits ProLiant Gen8–Gen10 Plus. BC (Basic Carrier) is used on Gen11 and later. SCN, SCC and SCM are NVMe, 3.5-inch converter and M.2 versions of the Smart Carrier. Match the carrier to your server generation first.
Disclosure: SSDtrader sells HPE-branded and generic drives for ProLiant servers. Explanations below are based on HPE's Solid State Disk Drives QuickSpecs and HPE PartSurfer data as reproduced by the parts listings linked in the sources. Always confirm a part on HPE PartSurfer or in your server's QuickSpecs.
HPE has one of the most systematic, and most confusing, part-number schemes in the server industry. The same physical SSD can appear under an option number, a spare number, an assembly number and a model number. Two drives that look identical may not fit the same server because of the carrier. And descriptions are packed with abbreviations: "1.92TB SATA 6G Read Intensive SFF BC Multi Vendor".
This guide decodes each piece so you can order the right drive the first time. It covers part-number types, carrier codes, workload and performance classes, "multi vendor" drives and how to cross-reference a part.
What are the different HPE part numbers?
| Number type | Format | Example | What it is used for |
|---|---|---|---|
| Option part number | 6 characters + -B21 | P40499-B21 | Orderable product kit sold through HPE channels; includes the carrier |
| Spare part number | 6 characters + -001 | P41558-001 | Service replacement used by HPE support; what you often find in used and refurbished stock |
| Assembly part number | 6 characters + -00x | (varies) | Internal build number printed on some labels |
| HPE model number | Alphanumeric string | VK000150GWCNN, VK0800GEYJT | Printed on the drive label; identifies the HPE-qualified drive model and firmware family |
An option number and its spare number refer to the same drive. For example, listings show P40560-B21 (800GB SAS 12G Mixed Use SFF BC) pairs with spare P41558-001, and P21143-B21 (3.84TB SAS 12G Read Intensive SFF SC) pairs with spare P22637-001. When buying used drives, sellers usually quote the spare number from the label. When ordering new kits, quote the option number.
Older HPE parts use six-digit numbers without the leading P, for example 816879-B21 / 817061-001. The structure is the same.
What do HPE carrier codes mean?
The carrier is the tray the drive is mounted in. It must match the server's bays.
| Code | Carrier | Typical servers |
|---|---|---|
| SC | Smart Carrier (2.5-inch SFF) | ProLiant Gen8, Gen9, Gen10, Gen10 Plus |
| SCN | Smart Carrier NVMe (2.5-inch) | Gen10 / Gen10 Plus NVMe bays |
| SCC | Smart Carrier Converter (2.5-inch drive in 3.5-inch LFF bay) | Gen8–Gen10 LFF servers |
| SCM | Smart Carrier M.2 (M.2 drives on an SFF carrier) | Gen10 / Gen10 Plus |
| BC | Basic Carrier (2.5-inch SFF, non-smart, hot-plug) | ProLiant Gen11 and Gen12 |
| LPC | Low Profile Converter (LFF) | Gen10 LFF and others |
| EC1 | E3.S thin carrier | Newer platforms with E3.S bays |
The Smart Carrier has an LED ring and a "do not remove" indicator; the Basic Carrier is simpler. The two are not interchangeable: an SC drive does not fit a Gen11 BC bay, and a BC drive does not fit a Gen10 SC bay. HPE's carrier key decoder in the SSD QuickSpecs describes the BC as a non-smart, hot-plug carrier.
If you have a bare drive, you can move it between carriers; the drive itself is usually the same. But a drive sold as an SC kit is listed in HPE's systems only for SC servers, and support will reference that option number.
What do RI, MU and WI mean in HPE descriptions?
HPE groups SSDs by endurance:
- Read Intensive (RI): endurance up to about 1 drive write per day. Older HPE generations also used "VRO" (very read optimized) and "RI-2" labels.
- Mixed Use (MU): balanced read/write, typically around 3 DWPD.
- Write Intensive (WI): highest endurance for write-heavy workloads.
For NVMe drives, HPE adds a performance class: Mainstream Performance, High Performance or Very High Performance. For example, a 1.92TB NVMe Gen4 Mainstream Performance Read Intensive SFF SC U.3 drive is a different product from a High Performance Mixed Use drive of the same size.
To choose between them, measure your write volume. See what is a read-intensive SSD and TBW and DWPD explained.
What does "Multi Vendor" mean?
Many HPE descriptions end with "Multi Vendor". It means HPE may ship the option from any of several qualified manufacturers (for example Samsung, Micron, Kioxia or Intel/Solidigm) under the same part number, with HPE firmware. The capacity, interface, endurance class and carrier are guaranteed; the underlying drive model is not. Descriptions that name a model, such as "PM1645a", "PM893a", "PE8010" or "5300P", specify the manufacturer's drive.
For a RAID set, it is good practice to use the same underlying model and firmware. When you buy multi-vendor spares in quantity, ask the supplier which model you will receive.
How do you read a full HPE drive description?
Take "HPE 1.6TB NVMe Gen4 High Performance Mixed Use SFF SCN U.3 PM1735a SSD":
| Part of description | Meaning |
|---|---|
| 1.6TB | Capacity |
| NVMe Gen4 | PCIe 4.0 NVMe interface |
| High Performance | HPE NVMe performance class |
| Mixed Use | Endurance class (~3 DWPD) |
| SFF | 2.5-inch small form factor |
| SCN | Smart Carrier NVMe |
| U.3 | Connector standard (works in U.3 tri-mode and most U.2 NVMe bays) |
| PM1735a | Underlying Samsung drive model |
For the Samsung models HPE ships, see our PM1733 vs PM1735 guide and the Samsung enterprise lineup.
Do non-HPE drives work in ProLiant servers?
Generic drives in a compatible carrier usually work for data. The trade-offs are similar to Dell's:
- iLO and Smart Storage Administrator may not show full wear data, and the drive status LED on a Smart Carrier may not behave normally.
- Smart Array controllers in RAID mode usually accept third-party drives. Some fan-speed logic may raise fan speeds when it cannot read the drive's temperature in the expected way.
- HPE support will not cover the drive, and HPE firmware updates will not apply.
For production servers under HPE support, buy HPE-branded drives. For out-of-warranty or lab servers, generic enterprise drives are a common, cheaper path.
How to cross-reference an HPE part
- Read the label. It shows the spare number (-001), often the option number, the model number and the HPE firmware.
- Look it up in HPE PartSurfer to see the description and the option/spare relationship.
- Check the server's QuickSpecs to confirm the option number is supported on your ProLiant model and generation.
- Confirm the carrier (SC vs BC, SFF vs LFF) for your bays.
- Send the number to your supplier. We can match spares, options and equivalents.
Buying HPE drives from SSDtrader
We stock and source HPE SSDs and hard drives for ProLiant Gen8 through Gen11, in new, open-box, refurbished and used grades. Browse HPE ProLiant server drives, or send option or spare numbers through the quote form. We reply within four working hours, with a formal quote within 24 hours. There is no minimum order, and volume pricing starts at 10 pieces.
Not sure which drive fits your server? Use our server drive compatibility finder or request a bulk / project quote.
Questions buyers ask
What does -B21 mean on an HPE part number?
It marks an option part number: the orderable product kit, usually including the carrier.
What does -001 mean on an HPE part number?
It marks a spare part number, used for service replacements. It refers to the same drive as the matching -B21 option.
Can I use a Gen10 Smart Carrier drive in a Gen11 server?
Not in its Smart Carrier. Gen11 uses the Basic Carrier (BC). The bare drive may be supported if HPE lists an equivalent BC option for Gen11.
What is HPE Multi Vendor?
HPE may fulfil the part with drives from different qualified manufacturers, all with HPE firmware and the same specifications.
What does VRO mean on older HPE SSDs?
Very Read Optimized: an older HPE endurance class below standard read-intensive, used for read-dominant workloads.
Where do I find an HPE drive's spare number?
On the drive label, often marked "SPARE" or "SPS-DRV", and in HPE PartSurfer.
Related guides
- Dell EMC SSD part number guide
- NetApp drive part numbers explained
- Samsung part number suffixes
- Buying refurbished enterprise SSDs